De-dietrich C 230 Eco Manual de usuario

Busca en linea o descarga Manual de usuario para Radiadores De-dietrich C 230 Eco. DE DIETRICH C 230 Eco User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - C 230 ECO

C 230 ECOGas fired condensing boilerUser Guide300015144-001-CEND000651

Pagina 2 - Contents

10C 230 ECO 20/02/09 - 300015144-001-C4.2.2 Control panel K3Make all settings on the master boiler fitted with a DIEMATIC-m3control panel Press the*ke

Pagina 3 - 1Introduction

1120/02/09 - 300015144-001-C C 230 ECO4.3 Stopping the boiler- Cut the power supply to the boiler.- Close the gas valve.Don't forget the risk of

Pagina 4 - 2.2 Recommendations

12C 230 ECO 20/02/09 - 300015144-001-C6 Troubleshooting6.1 Rating plateDXX-XX

Pagina 5 - 3 Description

1320/02/09 - 300015144-001-C C 230 ECO6.2 Messages - Faults6.2.1 MessagesMessageCode no.Probable causes ActionSHOW REM. CTRLThe message SHOW REM.CTRL

Pagina 6 - 4 Operating the appliance

14C 230 ECO 20/02/09 - 300015144-001-CMessages are not memorised.BL.BAD PSU18The PSU is not compatible with the PCU- Switch the boiler off and switch

Pagina 7 - 024681012141618202224

1520/02/09 - 300015144-001-C C 230 ECO6.2.2 FaultsFaults Code no. Probable causes ActionBOILER S.FAIL.32 The boiler sensor is short circuited - Reset

Pagina 8 - D0006 37

16C 230 ECO 20/02/09 - 300015144-001-CTA-S FAILURE Internal problem.- Switch off the current. - Contact the professional responsible for maintenance o

Pagina 9 - 4.2 Changing the settings

1720/02/09 - 300015144-001-C C 230 ECOBURNER FAILURE 14- No flame after 5 ignition attempts- No ignition spark- Reset the box- Check the correct con

Pagina 10 - 4.2.2 Control panel K3

18C 230 ECO 20/02/09 - 300015144-001-CCS OPEN FAIL 39 The contact inlet CS is open- Check the cause of the open contact CS- Reset the boxFAIL. UNKNO

Pagina 11 - 5 Checking and maintenance

1920/02/09 - 300015144-001-C C 230 ECOThe last ten failures are memorised in the paragraph #DEF.HISTORYZSee: "Parameter and input/output check (

Pagina 12 - 6 Troubleshooting

2C 230 ECO 20/02/09 - 300015144-001-CContents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 13 - Messages

20C 230 ECO 20/02/09 - 300015144-001-C6.3 Technical characteristicsC 230-... Unit 85 130 170 210GeneralNumber of sections 3456Burner operation Modula

Pagina 14

2120/02/09 - 300015144-001-C C 230 ECO(1) For Italy(2) G20 - Gas H7 Energy savingsHere are a few tips for saving energy:- Install reflector panels beh

Pagina 15 - 6.2.2 Faults

22C 230 ECO 20/02/09 - 300015144-001-CWarrantyYou have just purchased one of our appliances and we thank youfor the trust you have placed in our produ

Pagina 16

2320/02/09 - 300015144-001-C C 230 ECO

Pagina 17

© CopyrightAll technical and technological information contained in these technical instructions, as well as anydrawings and technical descriptions su

Pagina 18

320/02/09 - 300015144-001-C C 230 ECO1Introduction1.1 Used symbolsCaution dangerRisk of injury and damage to equipment. Attention must bepaid to the

Pagina 19

4C 230 ECO 20/02/09 - 300015144-001-C2 Safety instructions and recommendations2.1 Safety instructions Fire hazardDo not stock products of an inflamm

Pagina 20 - 6.3 Technical characteristics

520/02/09 - 300015144-001-C C 230 ECO3 Description262721199151718201312 1425242322130282923547861011160D 006581 Flue gas discharge duct2Measurement po

Pagina 21 - 7 Energy savings

6C 230 ECO 20/02/09 - 300015144-001-C4 Operating the appliance4.1 Control panel4.1.1 Control panel DIEMATIC-m3 Electromechanical components1. General

Pagina 22 - Warranty

720/02/09 - 300015144-001-C C 230 ECO Display024681012141618202224A3 4 5 691011821BC7SUNDAY1 Text and numerical display2 Graphic display bar for the

Pagina 23

8C 230 ECO 20/02/09 - 300015144-001-C4.1.2 Control panel K31. General ON 8 / OFF 7 switch2. Reset button3. Connector for the programming tool4. Timed

Pagina 24 - DE DIETRICH THERMIQUE

920/02/09 - 300015144-001-C C 230 ECO4.2 Changing the settings4.2.1 Control panel DIEMATIC-m3 Keys accessible when the flap is closed  Keys accessib